KGRKJGETMRETU895U-589TY5MIGM5JGB5SDFESFREWTGR54TY
Server : Apache/2.2.17 (Unix) mod_ssl/2.2.17 OpenSSL/0.9.8e-fips-rhel5 DAV/2 PHP/5.2.17
System : Linux localhost 2.6.18-419.el5 #1 SMP Fri Feb 24 22:47:42 UTC 2017 x86_64
User : nobody ( 99)
PHP Version : 5.2.17
Disable Function : NONE
Directory :  /proc/21571/root/usr/share/doc/mgetty-1.1.33/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Current File : //proc/21571/root/usr/share/doc/mgetty-1.1.33/modems.db
WARNING: most information in this file is for older versions of policy.h,
some of the definition names have changed, others are used slightly
different. Make sure that you have read *ALL* of the comments in there,
and understand them!

gert

----------------------------------------------------
Modem brand/model: 	"Dynalink 9624AP"
at+fmfr?		EXAR
at+fmdl?		9648,2,E,290X
at+frev?		10, 10, 92   REVISION  X 2.0
ati3			ADN-06
ati4			MARROW 2900KSX V2.0B 11-05-1992
tested on:		linux 0.99p10
working:		sendfax, mgetty(?)
remarks: avoid this cheap and nasty modem if you possibly can. It needs:
         delay(500) at the end of fax_open_device(), sendfax.c line 111
         delay(500) after the call to fax_send_page(), sendfax.c line 533
         "\d\d\d" in all the AT-commands in init_chat_seq, mgetty.c
contributor:		a.j.scholl@durham.ac.uk
#define DATA_FLOW	FLOW_HARD
#define FAXREC_FLOW	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW	FLOW_HARD 
#define FAX_SEND_BAUD 	19200
#define FAX_MODEM_HANDSHAKE ""
#define FAX_SET_CSTOPB	1        /* for when you've added this option :-) */
----------------------------------------------------
Modem brand/model: 	"Zoltrix Platinum Series 14.4"
at+fmfr?		ROCKWELL
at+fmdl?		RC32ACL
at+frev?		V1.410-AP39
ati3			
ati6			RCV144DP; Rev CA
tested on:		linux 0.99p7
working:		mgetty, sendfax
remarks:                great modem! In my uucp network of 16 machines,
			this modem averages at 1700 bps, while other
			brand name modems such as the Trailblazer PEP
			maxes out at about 1570. 
contributor:		whome!light-house!las@planix.com
#define DATA_FLOW	FLOW_HARD
#define FAX_COMMAND_DELAY 50
#define FAXREC_FLOW	FLOW_SOFT
#define FAXSEND_FLOW	FLOW_SOFT
#define FAX_SEND_BAUD 38400
#define FAX_MODEM_HANDSHAKE "AT&K3"
#define MODEM_INIT_STRING	"ATS0=0V1Q0&D3&K3%C1W1"
----------------------------------------------------
Modem brand/model:      PCMCIA Modem HOTLINE 960 CC HL9672CC
AT+FMFR?                HOTLINE
AT+FMDL?                Handy 9672 CC
AT+FREV?                Version 1.03H
ATI3                    V1.03DP
ATI4                    Handy 9672 CC H1_103
AT+FDCC=?               (0,1),(0-3),(0-2),(0-2),(0,1),0,0,(0-7)
tested on:              OS: Linux, Kernel: 1.0, Distribution: Slackware 1.2.0
			Computer: Toshiba T4700C Notebook
working:                sendfax, mgetty
contributor:            lauther@zfe.siemens.de
remarks:                can only do 9600 bps

#define DEFAULT_PORTSPEED       19200
#define MODEM_INIT_STRING       "ATS0=0Q0&D3&K3"
#define MODEM_CMD_SUFFIX        "\r"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW            FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD           19200
#define FAX_MODEM_HANDSHAKE     "AT&K3"
----------------------------------------------------
Modem brand/model:      Creatix (1&1) Polimedia 14400 voice / fax modem
AT+FMFR?                Creatix
AT+FMDL?                LC144VF
AT+FREV?                V1.41
ATI0			14400
ATI1			007
ATI3			V1.400/T4-DS29F
ATI4			Creatix Polymedia GmbH V1.41 29/11/93
ATI6			RCV144DPi Rev CA
AT+FDCC=?               (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7)
tested on:              ???
working:                sendfax, mgetty
contributor:            andreas@malcolm.in-chemnitz.de

#define DEFAULT_PORTSPEED	38400
#define MODEM_INIT_STRING	"ATS0=0Q0&D3&K6"
#define MODEM_CMD_SUFFIX	"\r"
#define DO_CHAT_SEND_DELAY	50
#define FAX_COMMAND_DELAY	50
#define DATA_FLOW       	FLOW_HARD
#define FAXREC_FLOW     	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    	FLOW_HARD | FLOW_SOFT
#define FAX_RECV_SWITCHBD 	19200
#define FAX_SEND_BAUD 		19200
#define FAX_MODEM_HANDSHAKE	"AT&K6"

Remark: &K6 is not a good idea on systems supporting RTS/CTS flow control.
        Better use &K3 instead. (gert).
----------------------------------------------------
Modem brand/model:      Creatix (1&1) Polymedia 14400 voice / fax modem
AT+FMFR?                ROCKWELL            
AT+FMDL?                RC32ACL             
AT+FREV?                V1.600-DS29F
ATI0                    14400
ATI1                    007
ATI3                    V1.600-DS29F
ATI4                    Creatix Polymedia GmbH germ V1.61 14/12/94
ATI6                    RCV144DPi Rev CA
AT+FDCC=?               (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7)
tested on:              Linux 1.2.8, 486/33, 16550A
working:                sendfax, mgetty, vgetty (see below), 0.99-Sep23
contributor:            jens@physiology.rwth-aachen.de

#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "AT&F0S0=0Q0&D3&K6"
#define MODEM_CMD_SUFFIX        "\r"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW            FLOW_HARD | FLOW_SOFT
#define FAX_RECV_SWITCHBD       19200
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     - nothing special given -

Remark: &K6 means RTS/CTS *and* XON/XOFF for that modem.
	This version (1.6) doesn't support ADPCM-3 ! AT#VBS=3 -> Error.
        In principle the modem works with vgetty, BUT
	the modem does not give any DLE-shielded code when recording from
        the telefone line. As long as you do fax sending or login-attempts
        during the greetin message, everything is fine. But during recording
        neither silence nor busy nor data/fax are recognized. So vgetty 
	records as long as the maximum time given for recording. (jens).
----------------------------------------------------
Modem brand/model: 	"Practical Peripherals PM14400FXMT"
at+fmfr?		2.30 (c) Practical Peripherals Inc. 1993.
at+fmdl?		PM14400FXMT [6R3] 2.30
at+frev?		Version 2.30
ati3			PM14400FXMT [6R3] Version 2.30 (c) Practical 
			Peripherals Inc. 1993.PM14400FXMT [6R3] Version 2.30 
			(c) Practical Peripherals Inc. 1993.
ati4			a097840F284C6703F
			bC60004000
			r1001111171012000
			r3000111010000000
tested on:		HP-UX 9.01
working:		mgetty (both fax and dialin)
remarks: 		Once I got all the settings correct it has
			worked very well.  It seems to have very
			good response even on 'dirty' lines.
contributor:		noorder@tac3.vv.hac.com
#define DATA_FLOW		FLOW_HARD
#define FAXREC_FLOW		FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW		FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD 		38400
#define FAX_MODEM_HANDSHAKE 	"AT&R0"
#define MODEM_INIT_STRING	"ATS0=0&Q9&D3&K4"
#define DEFAULT_PORTSPEED       38400
#define MODEM_CMD_SUFFIX        "\r"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define FAX_RECV_SWITCHBD	19200
-----------------------------------------------------------------------
Modem brand/model:      Practical Peripherals PM14400FXMT
at+fmfr?                2.42 (c) Practical Peripherals Inc. 1993.
at+fmdl?                PM14400FMXT [6R4] 2.42
at+frev?                Version 2.42
ati3                    PM14400FMXT [6R4] Version 2.42 (c) Practical Peripherals Inc. 1993.
ati4                    a097840F284C6703F
                        bC60004000
                        r1001111171012000
                        r3000111010000000
tested on:              Linux 1.0 (Slackware 1.2.0)
working:                sendfax, mgetty
remarks:                Good modem; can handle ALL incoming data calls at all
                        speeds, plus *MOST* incoming FAXes (some paper
                        machines give +FHNG:100 @ 2400 baud).  Good manual,
                        but (like others, no +F commands listed.  My guess is
                        about 75% Class 2 commands implemented.
contributor:            paul@edgewood.portland.or.us
#define DEFAULT_PORTSPEED       38400 /* 57600 w/ 'setserial spd_hi' */
#define FAX_RECV_SWITCHBD	19200
#define FAX_SEND_BAUD           19200
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW            FLOW_HARD | FLOW_SOFT
#define FAX_MODEM_HANDSHAKE ""
#define MODEM_INIT_STRING       "\\dATM0S0=0Q0&C1&D2&K3&Q5"
---------------------------------------------------
Modem brand/model:      "ZyXEL 1496 E+"
at+fmfr?                ZyXEL
at+fmdl?                U1496E  V 6.12 P
at+frev?                U1496E  V 6.12 P
ati			1496

tested on:              DEC OSF/1 v1.2-hybrid
			SCO Unix ODT 3.0
			Linux (various)
working:                sendfax, mgetty, vgetty
contributor:            Marc@Synergytics.Com
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD   38400
#define FAX_MODEM_HANDSHAKE "AT&H3"
#define MODEM_INIT_STRING "ATS0=0Q0&D3&H3&N0&K4"
---------------------------------------------------
Modem brand/model:      ZyXEL U1496EG+ 
AT+FMFR?                ZyXEL
AT+FMDL?                U1496EG V 6.12 P 
AT+FREV?		U1496EG V 6.12 P 
ATI3			(OK)
ATI4                    (OK)
AT+FDCC=? 		(0,1),(0-5),(0-2),(0-2),(0-1),(0),(0),(0-7)
tested on:              AIX 3.2.5
working:                sendfax, mgetty (both 0.20)
contributor:            hm@ix.de
remarks:                

#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "ATL0S0=0Q0&D3&H3&N0&K4"
#define MODEM_CMD_SUFFIX        "\r"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW            FLOW_SOFT
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     "AT&K3"

---------------------------------------------------

Modem brand/model:      GVC GM-144VBIS+
AT+FMFR?                EXAR
AT+FMDL?                9648,2,E,290X
AT+FREV?		GM-144VBIS+; RC9696/14
ATI3			170
ATI4                    GM-144VBIS+; RC9696/14
AT+FDCC=? 		(0-1),(0-3),(0-3),(0-2),(0-2),(0),(0),(0-7)
tested on:              AIX 3.2.5
working:                mgetty-0.20 
contributor:            hm@ix.de
remarks:                (sendfax is not tested and not intended to)

#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "ATL0S0=0Q0&D3\\\\Q3&S0%C\\\\N6"
#define MODEM_CMD_SUFFIX        "\r"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW            FLOW_SOFT
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     "AT\\\\Q3&S0"

----------------------------------------------------
Modem brand/model: 	"Aceex 1496"
at+fmfr?		EXAR
at+fmdl?		9624,2,E,290E
at+frev?		Sep-24-1991
ati3			
ati6			V.110 APR-30-1993 (ROCKWELL CHIP SET)
			DM1414/2A/RC144DP-21/PCB:490-09636-xx
			BZT POSTZULASSUNG-FIRMWARE VERSION:V.105
tested on:		SVR4.2 (UnixWare 1.1.1)
working:		mgetty, sendfax
remarks:                fax send / receive with max. 19200 bd
			This german telekom approved modem doesn't allow
			ATA without an incoming call (real RING). So
			kill -USR1 <mgetty-pid>  doesn't work. 
contributor:		100272.3376@compuserve.com (Achim Buerger)
#define DATA_FLOW	FLOW_HARD
#define FAX_COMMAND_DELAY 50
#define FAXREC_FLOW	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW	FLOW_HARD | FLOW_SOFT
#define DEFAULT_PORTSPEED 19200
#define FAX_SEND_BAUD	19200
#define FAX_MODEM_HANDSHAKE	"AT\\Q3&S0"
#define MODEM_INIT_STRING	"ATS0=0Q0&D3\\\\Q3%C1&N0&K3"
----------------------------------------------------
Modem brand/model:      "Dago Speed" from Speedy Technology, Koenigstein
at+fmfr?                ROCKWELL
at+fmdl?                RC32AC-W
at+frev?                V1.15
ati3                    V1.15
ati4                    RC144DP
tested on:              linux 0.99p15, 486DX50, UART 16550A
mgetty version:         0.21
working:                sendfax, mgetty
remarks:                sendfax: works perfectly (about 50 multi-page
                        faxes sent without problems)
                        mgetty: my Dago does not always recognize
                        fax calls correctly, especially from some fax
                        machines, but fax calls from a Creatix modem
                        are *almost* always recognized correctly.
                        When a fax call is recognized correctly, mgetty
                        has no problems. Defining FAX_RECV_SWITCHBD 19200
                        is necessary with my modem version.
                        Data calls are always recognized correctly
                        (tested with Creatix and Zyxel).
contributor:            schaefer@dfki.uni-sb.de (Ulrich Schaefer)
#define DEFAULT_PORTSPEED       38400
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD
#define FAXSEND_FLOW            FLOW_HARD
#define DO_CHAT_SEND_DELAY      100
#define FAX_COMMAND_DELAY       100
#define FAX_RECV_SWITCHBD	19200
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     "AT&K3"
#define MODEM_INIT_STRING       "ATS0=0V1Q0&D3&K3"

mgetty.c:  int toggle_dtr_waittime = 2000;   /* otherwise reset may fail */
-----------------------------------------------------------------------
Modem: SupraFax v.32bis
System Decstation 5000/200
OS:  Ultrix V4.2 (Rev. 96)


#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING  "AT&F2M0L0S0=0V1Q0&D3&K3%C1W1"
#define DEFAULT_MODEMTYPE "auto"
#define DO_CHAT_SEND_DELAY 50
#define FAX_COMMAND_DELAY 50
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW       FLOW_SOFT
#define FAXSEND_FLOW      FLOW_SOFT
#define FAX_RECV_SWITCHBD 19200
#define FAX_SEND_BAUD	19200
#define FAX_MODEM_HANDSHAKE "AT&K4"
at+fmfr? ROCKWELL
at+fmdl? V.32AC
at+frev? V1.71-02 TR14-Jxxx-001
ati3  V1.71-02 TR14-Jxxx-001 225
ati5 (c) 1992,93 Supra Corporation

Remark: see also Chris Junge's entry below
-----------------------------------------------------------------------
Modem brand/model:	Holmes Fax'em 96/24
AT+FMFR?		EXAR
AT+FMDL?  		9648,2,E,290X
AT+FREV?  		9/30/91 9.10 E  + V.23 REVISION 2.1D3
ATI3     		9/30/91 9.10 E  + V.23 REVISION 2.1D3
ATI4     		9/30/91 9.10 E  + V.23 REVISION 2.1D3
AT+FDCC=?  		(0,1),(0-3),(0-3),(0-2),(0-2),(0),(0),(0-7)
tested on:		OS: Linux, Kernel: 0.99pl13, Distribution: Slackware 1.1.2
			Computer: Compaq LTE Lite/25c Notebook
remarks:		introduce additional delays as mentioned in the
			mgetty-documentation
working:        	sendfax, mgetty
contributor:    	lauther@zfe.siemens.de
#define DEFAULT_PORTSPEED	19200
#define MODEM_INIT_STRING	"ATS0=0Q0&D3&H3&N0&K4"
#define MODEM_CMD_SUFFIX 	"\r"
#define DO_CHAT_SEND_DELAY 	50
#define FAX_COMMAND_DELAY 	50
#define DATA_FLOW		FLOW_HARD
#define FAXREC_FLOW		FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW		FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD   	19200
#define FAX_MODEM_HANDSHAKE 	""
-----------------------------------------------------------------------
Modem brand/model: 	"ESCOM High speed modem 14400"
at+fmfr?		EXAR
at+fmdl?		ROCKWELL 144DP
at+frev?		E.C. Version 7.1 Date code 921118
ati3			E.C. Version 7.1 Date code 921118
ati6			FM-144DHVBIS+/R1 V3.1o
tested on:		linux 1.1.20
working:		sendfax, (mgetty?)
remarks:                sendfax works only after padding blank lines
                        with zeros, e.g. by means of ..| g3cat -p 20 | ..
                        If this is not done, the machine at the
                        other end may hang up irrecoverably. 
contributor:		nuk111@cvx12.inet.dkfz-heidelberg.de
#define DATA_FLOW	FLOW_HARD
#define FAX_COMMAND_DELAY 50
#define FAXREC_FLOW	FLOW_SOFT
#define FAXSEND_FLOW	FLOW_SOFT
#define FAX_SEND_BAUD 19200 (38400 seems to be o.k., too)
#define FAX_MODEM_HANDSHAKE "AT\\Q3\\N6"
#define MODEM_INIT_STRING	"ATS0=0Q0&D3\\Q3\\N6"
-----------------------------------------------------------------------
Modem brand/model:	ESCOM Data Hawk 14400
at+fmfr?		EXAR
at+fmdl?		ROCKWELL 144DP
at+frev?		E.C.  Version : 7.1
			Date code 921118
	
			CURRENT COUNTRY : 5  GERMANY
ati1			122

			FM-144DHVBIS+/R1  V3.1o
ati3			CURRENT COUNTRY : 5  GERMANY
ati6			FM-144DHVBIS+/R1  V3.1o

			MODEM CHIP : ROCKWELL RC144DP H-CODE
	
			FAX CLASS 2
contributor:	stg@gandalf.han.de
-----------------------------------------------------------------------
Modem brand/model: 	"Boca V.32bis"
at+fmfr?		ROCKWELL
at+fmdl?		RC32ACL
at+frev?		V1.005
ati3			V1.005
ati4			Boca Research, M144GRA
tested on:		SINIX-L 5.40 A20N5 MX300I i386
working:		sendfax, mgetty/fax receive
remarks: Not really tested, it simply works stable enough for me.
         The special condition is that the MX300 on which mgetty runs
         has no hardware handshake. 
contributor:		fte@gecko.de (Frank Tegtmeyer)
#define DEFAULT_PORTSPEED	19200
#define MODEM_INIT_STRING	"ATS0=0Q0" all other defined in modem setup
#define DATA_FLOW	FLOW_SOFT
#define FAXREC_FLOW	FLOW_SOFT
#define FAXSEND_FLOW	FLOW_SOFT
#define FAX_SEND_BAUD 19200
#define FAX_MODEM_HANDSHAKE ""
-----------------------------------------------------------------------
Modem brand/model:	Supra FAX Modem V.32bis
at+fmfr?		ROCKWELL
at+fmdl?		V.32AC
at+frev?		V1.80-06v TR14-Jxxx-001
ati3			V1.80-06v TR14-Jxxx-001 216
ati4			a007050C08484402F / bC60000000 / r16E5111151012000 / r3000111170000000
tested on:		Linux version 1.1.44
working:		sendfax, mgetty
contributor:		chris@cj.in-berlin.de
remarks: 		If ATi3 reveals v1.7x and/or you are having faxing problems,
			especially with drop-outs between pages. A fix is don't
			define &D3 in the MODEM_INIT_STRING. Use &D2 and define
			in mg_m_init.c: "\\d\\d\\d+++\\d\\d\\d\r\\dATZQ0V1", "OK"
			There is another bug with AT+FCLASS=0: it sets &K3 to &K0
			Here is a little patch:
*** mg_m_init.c.orig	Sun Aug 14 13:32:48 1994
--- mg_m_init.c	Sun Aug 14 10:51:27 1994
***************
*** 135,140 ****
--- 135,145 ----
      {
  	lprintf( L_MESG, "huh? Cannot set +FDCC parameters" );
      }
+ 
+     if ( mdm_command( "AT &K3", fd ) == FAIL )
+     {
+ 	lprintf( L_MESG, "cannot set &K3 handshake" );
+     }
      
      return SUCCESS;
  }

#define DEFAULT_MODEMTYPE	"auto"
#define DATA_FLOW		FLOW_HARD
#define FAX_COMMAND_DELAY	50
#define FAXREC_FLOW		FLOW_HARD
#define FAXSEND_FLOW		FLOW_HARD
#define FAX_SEND_BAUD		19200
#define FAX_RECV_SWITCHBD	19200
#define MODEM_INIT_STRING	"ATS0=0Q0&D3"
#define FAX_MODEM_HANDSHAKE	"AT&K3"
-----------------------------------------------------------------------
Modem brand/model:      "Telebit T2500"
ati4                    a037800C004420 b100000000
tested on:              linux 1.1p62, 486DX50, UART 16450A
mgetty version:         0.21
working:                mgetty
remarks:                No fax option available with this modem :-c
contributor:            frank@gzunda.mayn.sub.de (Stefan Frank (sf))
#define DEFAULT_PORTSPEED       19200
#define DATA_FLOW               FLOW_HARD
#define DO_CHAT_SEND_DELAY      500
#define FAX_COMMAND_DELAY       500
#define MODEM_INIT_STRING       "ATS0=0V1Q0&D3&K3"

mgetty.c:  int toggle_dtr_waittime = 2000;   /* otherwise reset may fail */
-----------------------------------------------------------------------
Modem brand/model:      U.S. Robotics Courier V.34 Fax
ati0                    2886
ati7                    Configuration Profile...

                        Product type           US/Canada External
                        Options                V32bis,Terbo,V.FC,V.34
                        Fax Options            Class 1/Class 2.0
                        Clock Freq             20.16Mhz
                        Eprom                  256k
                        Ram                    32k

                        Supervisor date        12/02/94
                        DSP date               12/02/94

                        Supervisor rev         6.0.5
                        DSP rev                1.0.6
tested on:              linux 1.0.9
working:                sendfax, mgetty-0.22
remarks: This "V.Everything" modem connects with V.34, V.FC, and V.32terbo
         in addition to the standard lower speeds (but not HST).  It has
         adaptive speed leveling to dynamically adjust to line conditions.
         It supports fax classes 1 and 2.0.  I use the linux spd_vhi serial
         port setting together with 38400 to lock the modem at 115200 baud.
         Note that it does not require the "#define FAX_USRobotics" in
         policy.h.  I use the default modem switches and all the default
         settings obtained by AT&F1 with one exception: I set ATT so that
         "ATD" will use tones to dial instead of pulses, by default.

	 When sending to some older fax machines (Amstrad, Pitney-Bowes,
	 Sharp) fails, try setting S36=14 for longer timeouts. Thanks to
	 sbromwic@usr.com for this hint.

contributor:            hemphill@alumni.caltech.edu
contributor2:		cb@medat.de (Christoph Brinck)

#define DEFAULT_PORTSPEED 38400
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_HARD
#define FAXSEND_FLOW    FLOW_HARD 
#define FAX_SEND_BAUD   38400
#define FAX_MODEM_HANDSHAKE "AT&H1"
#define MODEM_INIT_STRING "AT&F1&S4T"
-----------------------------------------------------------------------
Modem brand/model:      Intel High-Speed (14400) Internal Faxmodem 
AT+FMFR?                EXAR
AT+FMDL?                ROCKWELL 144DP
AT+FREV?                INTEL 14400I  V1.7
                        MODEM CHIP : ROCKWELL RC144DP
                        FAX CLASS 2
ATI1		        046
                        INTEL 14400I  V1.7
ATI3		        E.C.  Version : 1.6
                        Date code 930511
ATI4                    INTEL 14400I  V1.7
                        MODEM CHIP : ROCKWELL RC144DP
                        FAX CLASS 2
ATI5                    as ATI4
ATI6                    as ATI4

AT+FDCC=?               (0-1),(0-5),(0-3),(0-2),(0-2),(0),(0),(0-7)

tested on:              Linux 1.1.76, mgetty-sendfax v0.22
working:                sendfax, mgetty
contributor:            jeffrey@thompson.itm.org
remarks:                Make sure and use &D2 and not &D3. &D3 is reset to &D0!
#define DEFAULT_PORTSPEED	19200
#define MODEM_INIT_STRING	"ATS0=0Q0&D2\\\\Q3\\\\N3\"H3"
#define MODEM_CMD_SUFFIX	"\r"
#define DEFAULT_MODEMTYPE "auto"
#define DO_CHAT_SEND_DELAY	50
#define FAX_COMMAND_DELAY	50
#define DATA_FLOW       	FLOW_HARD
#define FAXREC_FLOW     	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    	FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD 		38400
#define FAX_MODEM_HANDSHAKE "AT\\Q3&S0" 
#define FAX_MODEM_TTYS	"ttyS2"        (not cua2)

And an AT&V of my modem settings:

ACTIVE PROFILE:
B1 E1 L2 M0 Q0 T V1 X4 Y0 &C1 &D2 &G0 &P0 &S0 &Y0
\A3 %A013 \C0 %C1 %E1 \G0 \J0 \K5 \N3 \Q3 \T000 \V2 \X0 -J1 "H3
S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:120
S08:002 S09:006 S10:014 S11:070 S12:050 S18:255 S23:17H S25:005 S26:001
-----------------------------------------------------------------------
Modem brand/model:      Creatix LC 288 FC
at+fmfr?                ROCKWELL
at+fmdl?                AC/VFC
at+frev?                V1.000-DS39 VFC
ati0                    28800
ati3                    V1.000-DS39 VFC
ati4                    Creatix Polymedia GmbH  V1.00  18/08/94
ati6                    RC288DPi Rev 05BA
at+fdcc=?               (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7)
tested on:              linux 1.1.54, 486DX50, UART 16550A
mgetty version:         0.21, 0.23
working:                sendfax, mgetty
remarks:                sendfax and mgetty (fax & logins) work, serving
			documents for polling with mgetty works, but polling
			with sendfax does not work (yet)
                        great modem!
contributor:            schaefer@dfki.uni-sb.de (Ulrich Schaefer)
#define DEFAULT_PORTSPEED       38400        (115200 effectively)
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD
#define FAXSEND_FLOW            FLOW_HARD
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define FAX_RECEIVE_SWITCHBD 19200
#define FAX_SEND_BAUD           38400        (115200 effectively)
#define FAX_MODEM_HANDSHAKE     "&K3"
#define MODEM_INIT_STRING       "ATS0=0V1Q0&D3&K3&C1"

alternatively, leave everything as it is by default, and use

    switchbd 19200
    speed 38400
    init-chat "" \d\d\d+++\d\d\dATQ0E1V1H0 OK ATS0=0&D3&C1&K3 OK

in mgetty.config.
-----------------------------------------------------------------------
Modem brand/model: 	"TKR Terbo Line"
at+fmfr?		FAX TEST CODE
at+fmdl?		AT&T
at+frev?		FAX Version 3.99
ati3			TKR Terbo Line 19K2/010-Q
ati4			007040C004000
tested on:		Linux version 1.2.1, mgetty 0.23
working:		sendfax, mgetty/fax receive, dialout
remarks:  The Firmware version 010 (ati3) is the first that is able
          to decide wether a call is from a modem or fax. Earlier versions
          receive only in fax mode. You can get the newest version from the
          TKR bbs (+49 431 336199) or by snail-mail (Phone: +49 431 34589).
contributor:		fte@impulse.ris.de (Frank Tegtmeyer)
#define DEFAULT_PORTSPEED	19200
/* #define USE_GETTYDEFS */
#define MODEM_INIT_STRING	"ATX3S0=0Q0&D2&C1&K3"
#define MODEM_CMD_SUFFIX "\r\n"
#define DEFAULT_MODEMTYPE "cls2"
#define DO_CHAT_SEND_DELAY 50
#define FAX_COMMAND_DELAY 50
#define DATA_FLOW	FLOW_HARD
#define FAXREC_FLOW	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW	FLOW_HARD | FLOW_SOFT
/* #define FAX_RECV_SWITCHBD 19200 */
#define FAX_SEND_BAUD 19200
/* #define FAX_SEND_SWITCHBD 19200 */
/* #define FAX_MODEM_HANDSHAKE "AT&H3" */
/* #define FAXSEND_NO_XON */
-----------------------------------------------------------------------
Modem brand/model:	XLink V.34 + V.FC
AT+FMFR?                GVC
AT+FMDL?                ROCKWELL 144DPI
AT+FREV?                KA1131-00
ATI0                    288
ATI3                    E.C.  Version : T
ATI4                    F-1128V/R6 (GM) V6.18.4
                        MODEM CHIP : ROCKWELL RC288DPi
                        FAX CLASS 1 AND CLASS 2
AT+FDCC=?               (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)
tested on:		linux 1.2.6, 486DX40, UART16550A
mgetty version:		0.23 (Dec 23, 1994)
working:		mgetty, sendfax
remarks:		sendfax and mgetty (fax & logins) work, polling
			with sendfax does not work (yet)
contributor:            tom@umibox.hanse.de (Thomas Milde, DL1HBT)
#define DEFAULT_PORTSPEED       38400
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD
#define FAXSEND_FLOW            FLOW_HARD
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define FAX_RECEIVE_SWITCHBD	19200
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     "&K3"
#define MODEM_INIT_STRING       "ATS0=0V1Q0&D3&K3&C1"
-----------------------------------------------------------------------
Modem brand/model:      CPV Stollmann Delta V.34
at+fmfr?                GVC
at+fmdl?                ROCKWELL 144DPI
at+frev?                KA1131-00
ati0                    288
ati3                    E.C.  Version : T
ati4                    F-1128V/R6 (GM) V6.18.3
                        MODEM CHIP : ROCKWELL RC288DPi
                        FAX CLASS 1 AND CLASS 2
at+fdcc=?               (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)
tested on:              linux 1.1.54, 486DX50, UART 16550A
mgetty version:         0.23 of April 10, 1995
working:                mgetty and sendfax, no polling available
contributor:		schaefer@dfki.uni-sb.de (Ulrich Schaefer)

policy.h:
    everything default

mgetty.config:
    speed 115200
    switchbd 19200
    init-chat ATS0=0V1Q0&D3&C1&K3 OK
-----------------------------------------------------------------------
Subject: new entry mgetty+sendfax modem.db
From: Thomas Kuerten <kuerten@informatik.tu-muenchen.de>
To: gert@greenie.muc.de (Gert Doering)

Modem brand/model:     USRobotics Sportster V.34 28.800 Fax Modem
AT+FMFR?               ???
AT+FMDL?               ???
AT+FREV?               ??? 
ATI0                   2886
ATI1                   05B1
ATI4   USRobotics Sportster 28800 Fax Settings...
       B0  E1  F1  M1  Q0  V1  X4
       BAUD=115200 PARITY=N  WORDLEN=8
       [..]
ATI7
       Configuration Profile...
       Product type           Germany External
       Options                V32bis,V.FC,V.34
       Fax Options            Class 1/Class 2.0

tested on:              Linux 1.0 (Slackware 1.2.0)
                        Kernel 1.1.59 and 1.2.0
tested on:              Solaris 2.5
			SunOS 4.1.3 and 4.1.4
working:                sendfax, mgetty
remarks:                "#define FAX_USRobotics" is NOT intended to use with
                        this modem, instead all works fine without, and problems
                        occur IF this is defined.
                        Best modem I ever had, all works fine for sendfax
                        and receivefax, different faxes received, multipage
                        (up to 10) from different countries (Scotland, Italy).
                        mgetty remote login not yet tested. Modem has great
                        connects with V.34 28.800 in data mode, giving rates of
                        4500 cps for uncompressed and 3400 for compressed data.
                        But only good for stable telefon lines, not very good
                        at scratchy or analog connections.

			If you have caller ID on your phone line, add
			AT#CID=1 to your init chat sequence, and mgetty
			will be able to write the Caller ID to the log
			files.

WARNING: many USR Sportster models are completely unable to send and/or
	 receive faxes.  So, if faxing is important for you, DO NOT GET
	 AN USR SPORTSTER.  (Get an USR Courier, works very good).

contributor:            kuerten@informatik.tu-muenchen.de
contributor:            rrb@cqs.ch
 
/* changed values in policy.h: */
#define MODEM_INIT_STRING    "ATZ"
#define FAX_MODEM_HANDSHAKE  "AT&H3&I2&R2S7=90"

/* unchanged: */
#define DEFAULT_PORTSPEED     38400      /* 115200 w/ 'setserial spd_vhi' */
#define DATA_FLOW             FLOW_HARD
#define FAXREC_FLOW           FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW          FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD         38400
#define DEFAULT_MODEMTYPE     "auto"
--------------------------------- schnibbel ---------------------------------
Modem: SupraFaxModem 288 V34

tested on:      OS: Linux 1.3.28
                Computer: 486dx2/66 PCI system with 16450
working:        mgetty, sendfax, Version 0.98
contributor:    hohndel@aib.com (Dirk H. Hohndel)

at+fmfr?        Supra Corporation   
at+fmdl?        SupraFAXModem 288
at+frev?        V1.200-02-V34_DS
ati7            RC288DPi Rev 04BC

#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "ATS0=0Q0&D3&C1&K3"
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    FLOW_HARD | FLOW_SOFT
#define FAX_RECV_SWITCHBD 19200 
all other values left at "default".
--------------------------------- schnibbel ---------------------------------
Modem: Dynalink 1414VE
contributor: sakari@picea.hut.fi

#define MODEM_INIT_STRING	"ATS0=0N1Q0&D3&K3&Q5"
/*#define FAX_MODEM_HANDSHAKE "AT&H3"*/

all other values left at "default"
-----------------------------------------------------------------------
Modem brand/model:      U.S. Robotics Courier High Speed Modem
                        Dual Standard V.34 Fax with V.Fast Class and
V.32bis
ati0                    3366
ati7                    Configuration Profile...

                        Product type           Germany External MSK
                        Options                HST,V32bis,Terbo,V.FC,V.34
                        Fax Options            Class 1/Class 2.0
                        Clock Freq             20.16Mhz
                        Eprom                  256k
                        Ram                    32k

                        Supervisor date        11/07/95
                        DSP date               07/05/95

                        Supervisor rev         049-6.2.2
                        DSP rev                1.2.2

tested on:              linux 1.2.13
working:                sendfax, mgetty-0.99 from Feb 25, 1996
remarks:  it is very important to specify S9=3,
          default value does not work
contributor:            vnm@rzbt.fh-hamburg.de

policy.h:
#define DEFAULT_PORTSPEED       115200
#define MODEM_INIT_STRING       "AT&F&A3&B1&H1&R2&D2&C1X7S0=0S9=3S7=90"
#define MODEM_CMD_SUFFIX        "\r"
#define DEFAULT_MODEMTYPE       "auto"
#define DO_CHAT_SEND_DELAY      50
#define FAX_COMMAND_DELAY       50
#define DATA_FLOW               FLOW_HARD
#define FAXREC_FLOW             FLOW_HARD
#define FAXSEND_FLOW            FLOW_HARD
#define FAX_SEND_BAUD           38400
#define FAX_MODEM_HANDSHAKE     "AT&H1"
DIP switches:
	 1 OFF 2 OFF 3 ON 4 OFF 5 OFF 6 OFF 7 OFF 8 ON 9 ON 10 OFF
-----------------------------------------------------------------------
Modem brand/model:      "Blatzheim GM-288Vc+ FAX"
at+fmfr?                GVC
at+fmdl?                ROCKWELL 144DPI
at+frev?                KA1131-00
ati3                    E.C.  Version : R
ati4                    GM-288Vc+ FAX  V6.23  Blatzheim GmbH, Bonn
			MODEM CHIP : ROCKWELL RC288DP/VFC
			FAX CLASS 1 AND CLASS 2
AT+FDCC=?		(0,1),(0-5),(0-3),(0-2),(0,1),(0),(0),(0-7)
tested on:              linux 1.3.95, Pentium 100, UART16550A
working:                sendfax, mgetty-0.98
remarks:		no FAX polling mode (neither client nor server);
			newer V.34 modem not tested (my modem has only
			V.fast-class); no FAX Class 2.0 (only Class 2).
policy.h:		#define FAX_SEND_INGORE_CARRIER   /* required!! */
mgetty.config:		speed 38400
			switchbd 38400
			init-chat "" \d\d\d+++\d\d\dAT OK ATH0 OK AT&FB2E0L1M0S0=0 OK
sendfax.config:		modem-init AT&FB2E0L1M0S0=0
			switchbd 38400
			speed 38400
contributor:		thielen@lpr.e-technik.tu-muenchen.de
-----------------------------------------------------------------------
Modem brand/model:      "AT&T" (1428VQE) (no-brand manufacturer using AT&T
			chipset).
at+fmfr?                AT&T
at+fmdl?                HSM288xCF
at+frev?                V4.00
ati3                    DDS-03 9/27/95
ati4                    007040C0040000
tested on:              linux 1.2.1
working:                mgetty (data incoming, login and incoming fax)
remarks: 		This is the setup for this modem as of
			my mgetty.config:
		port ttyS1
		speed 38400
		init-chat "" \d\d\d+++\d\d\d\dAT&F OK ATZ OK ATE0L0 OK
		modem-type cls2
		switchbd 19200
			MAKE SURE ATE0 is selected. This modem defaults to
			echo on (ATE1) and that confuses mgetty causing
			fax reception to fail.
contributor:            rr@mn.village.it (Ruggero Ruberti)
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT 
-----------------------------------------------------------------------
Modem:              MVP288XV Cardinal 28800 ext. voice/fax/modem 
OS:                 Linux 1.3.97 on pentium-120
Init:               AT&F
/etc/mgetty.config: switchbd 19200      # No faxes else!
                    modem-type cls2     # works without this also
                    All other settings are untouched.
contributor: georgiev@generation.net
-----------------------------------------------------------------------
Modem brand/model:     ViVa 14.4/Fax from Computer Peripherals
AT+FMFR?               ROCKWELL
AT+FMDL?               RC32ACL
AT+FREV?               V1.000
ATI0                   14400
ATI1                   007
ATI4		AT-1414PKM V1.00 STANDARD VERSION 4.7.1993
AT&V
ACTIVE PROFILE:
B0 E1 L1 M1 N1 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0

tested on:              Solaris 2.5
                        SunOS 4.1.3 and 4.1.4
working:                sendfax, mgetty
remarks:                
contributor:            rrb@cqs.ch

/* changed values in policy.h: */
#define MODEM_INIT_STRING    "ATZ"
#define FAX_MODEM_HANDSHAKE  "AT&K3"
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Modem brand/model:      "1&1 Speedster 14400"
AT+FMFR?                CIS
AT+FMDL?                CEUSBEXX V1.03 31/01/96
AT+FREV?                VERSION 1.03   01-05-01-01
ATI0                    144
ATI1                    048
ATI3                    CEUSBEXX V1.03 31/01/96
ATI4                    UMC V.32bis/FAX/VOICE MODEM
ATI6                    
AT+FDCC=?               (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)
tested on:              Sun Solaris 2.5 with Sun C-Compiler
working:                sendfax
remarks:                mgetty not tested (no need for it at the moment)
contributor:            Alexander.Zimmermann@FMI.Uni-Passau.De

#define DEFAULT_PORTSPEED     19200
#define MODEM_INIT_STRING     "ATS0=0Q0&D3&C1&K3"
#define FAX_SEND_BAUD         19200
#define FAX_MODEM_HANDSHAKE   "AT&K3"
#define FAX_MODEM_TTYS        "/dev/term/a"
#define FAXSEND_NO_XON        /* does not work without this !! */
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Date: Thu, 12 Sep 1996 15:50:33 +0200 (MET DST)

Thank you Gerd for your marvellous programm. And many thanks to all 
others involved in this endeavour. It's all set up and working fine on my 
machiene. As you adviced, I got me another modem. The Creatix 144VFi is 
sold now for 75DM. I think they are clearing it out. So if anybody likes 
it, get it now. By the way, the included software for DOS/win is nice but 
it doesn't work.

I have in my Linux Box this modem running with mgetty99-Aug26 and a 
Creatix ISDN Card (Baugleich mit Teles 16.0) with vboxgetty.
 
Since the voice functions work so well with ISDN, I didn't even try to 
get them working with the modem. It is used mainly for faxing and 
sometimes to call a BBS with no ISDN port. Everything else is done with 
the ISDN card. 

And here the configuration data for the modem.db:

Modem brand/model:      Creatix 144VFi PhoneMaster / fax modem
############################################################## 
AT+FMFR?                CIS
AT+FMDL?                CCUSBIXX V1.10 10/10/95
AT+FREV?                VERSION 1.10  01-05-01-01
ATI0			144
ATI1			134
ATI3			CCUSBIXX V1.10 10/10/95
ATI4			UMC V.32bis/FAX/VOICE MODEM
AT+FDCC=?               (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)
tested on:              kernel 2.0.15
working:                sendfax, mgetty
contributor:            weizenkeim@t-online.de

#define DEFAULT_PORTSPEED	38400
#define MODEM_INIT_STRING	"ATS0=0Q0&D3&K3"
#define MODEM_CMD_SUFFIX	"\r"
#define DEFAULT_MODEMTYPE       "cls2"
#define DO_CHAT_SEND_DELAY	50
#define FAX_COMMAND_DELAY	50
#define DATA_FLOW       	FLOW_HARD
#define FAXREC_FLOW     	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    	FLOW_HARD | FLOW_SOFT
#define FAX_RECV_SWITCHBD 	19200
#define FAX_SEND_BAUD 		19200
#define FAX_SEND_SWITCHBD 	19200 
#define FAX_MODEM_HANDSHAKE	"AT&K3"

-----------------------------------------------------------------------
Modem brand/model: 	"Bocamodem 14.4Kbps V.32bis"
at+fmfr?		ROCKWELL
at+fmdl?		RC32ACL
at+frev?		V1.300-AS29
ati3			V1.300-AS29
ati4			14,400 bps
tested on:		Linux 2.0.18 - Rocketport 8 port board, comtrol.1.11 driver module
working:		sendfax, mgetty
contributor:		don@marinelab.sarasota.fl.us
----
#ident "@(#)policy.h	3.6 96/07/09 Copyright (c) Gert Doering"
#define DEFAULT_MODEMTYPE "cls2"
#define DATA_FLOW	FLOW_HARD
#define FAXSEND_FLOW	FLOW_SOFT
#define FAX_SEND_BAUD 19200
----
# sendfax configuration file
fax-devices ttyR0
port ttyR0
  modem-handshake AT&K4
----
# mgetty configuration file
port ttyR0
  init-chat "" \d\d\d+++\d\d\dAT&F0\d\dS0=0M0E1X4Q0V1&C1&D2&K OK
  speed 19200
  data-only n

-----------------------------------------------------------------------
Modem model:     TKR TriStar (OEM Version of ELSA 28.8 TQV)
at+fmfr?         ""
at+fmdl?         "TKR TriStar"
at+frev?         "Ver. 1.16 vom 26.04.96"
ati              282
ati1             073
ati2             OK
ati3             Ver. 1.16 vom 26.04.96

Initstring:      ATL1V1&D3

tested on:       Linux Kernel 2.0.18 
working:         mgetty, vgetty, Fax, Voice, Data

remarks:         No changes in policy.h.
                 The Company TKR don't know about this Modem, and
                 Elsa ask for at+fmdl? and answer "call TKR"
                 Only for Voice-mode changes in voice.conf:
                 port_speed 38400 
		 port_timeout 15

contributor:     Karlo Gross  kg@orion.ddorf.rhein-ruhr.de
date:		 Mon Dec 16 19:52:34 1996

-----------------------------------------------------------------------
Modem brand/model: Creatix (?) 1&1 Speedster 14400U (grün)

AT+FMFR?		CIS
AT+FMDL?		CEUSBEXX V1.03 31/01/96
AT+FREV?		VERSION 1.03 01-05-01-01
ATI3			CEUSBEXX V1.03 31/01/96
ATI4			UMC V.32bis/FAX/VOICE MODEM
AT+FDCC=?		(0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)

system: Linux 2.0.18, i486
contributor: martin.stechert@t-online.de
Date: Sun, 12 Jan 1997 19:59:45 +0100 (CET)

#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "ATV1Q0"
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT
#define FAX_MODEM_HANDSHAKE "AT&K3"
#define FAX_DIAL_PREFIX "ATD"
#define FAXSEND_NO_XON			/* !!!!! */
-----------------------------------------------------------------------
Modem brand/model:      "IDC-1914BXL 19200 bps FAX-MODEM"
at+fmfr?                IDC
at+fmdl?                IDC
at+frev?                FAX Version 4.02
ati3                    IDC-1914BXL V.32terbo/V.42bis firmware by Mike Telis, Ver. 2.21
ati6                    Copyright INPRO, 1994-96. Tech support hot line (095) 265-0238.
tested on:              FreeBSD 2.1.0
working:                mgetty, sendfax (both 0.99.9)
remarks:                This modem is very popular with fidonet sysops in
                        Russia. It is certified by the Russian Ministry of
                        Communications and has a lot of features to tweak it
                        so that it works on poor lines where other modems
                        inevitably fail.  
remarks (2):            Something very weird is happening when receiving
                        faxes -- sometimes it just "stops"...!!??
contributor:            vas@vas.tomsk.su
date:			Mon, 27 Jan 97 19:46:18 +0700
#define DEFAULT_PORTSPEED       38400
#define MODEM_INIT_STRING       "ATZ"
#define MODEM_CMD_SUFFIX "\r"
#define DEFAULT_MODEMTYPE "auto"
#define DO_CHAT_SEND_DELAY 50
#define FAX_COMMAND_DELAY 50
#define DATA_FLOW       FLOW_HARD
#define FAXREC_FLOW     FLOW_SOFT
#define FAXSEND_FLOW    FLOW_SOFT
#define FAX_SEND_BAUD 19200
#define FAX_MODEM_HANDSHAKE "AT&K3"

-----------------------------------------------------------------------
Modem brand/model:      ELSA Microlink  28.8 TQV
AT+FMFR?                "ELSA, Aachen (Germany)"
AT+FMDL?                "MicroLink 28.8TQV"
AT+FREV?                "Ver. 1.10 vom 19.09.95"
ATI3                    Ver. 1.10 vom 19.09.95
AT+FDCC=?               (0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7)
tested on:              OS: Linux, Kernel: 2.0.25, Distribution: Suse 4.4
                        (mgetty-1.1.1-Jan28)
			Computer: Pentium 166
working:                sendfax, mgetty
contributor:            ai@easy.in-chemnitz.de
remarks:                same executable runs with slighly modified
                        init-chat with ELSA Microlink ISDN/TLV.34

#define DEFAULT_PORTSPEED	38400
#define MODEM_INIT_STRING     "\\dATS0=0Q0&D2&K3N1%E1&Q5"
#define DATA_FLOW	FLOW_HARD
#define FAXREC_FLOW	FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW	FLOW_HARD | FLOW_SOFT
#define FAX_SEND_BAUD 19200
#define FAX_MODEM_HANDSHAKE "AT\\Q3&S0"
-----------------------------------------------------------------------
Modem brand/model:      "Designer Modem (NoName)"
at+fmfr?                ACEEX
at+fmdl?                9624,2,E,290E
at+frev?                Sep-24-1991
ati3
ati6                    V2.7 MAY-27-94
                        DM1414/2A/RC144DP-21/PCB:490-09636-xx
                        BZT POSTZULASSUNG-FIRMWARE VERSION:V.105
tested on:              Linux 1.2.x and 2.0.x
working:                mgetty, sendfax
remarks:                Works fine.
contributor:            ht@rosenthal.ohz.north.de (Hermann Treu)
date:			21 Mar 97 16:49:30 +0100
#define FAX_COMMAND_DELAY 50
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    FLOW_HARD | FLOW_SOFT
#define DEFAULT_PORTSPEED 38400
#define FAX_SEND_BAUD   19200
#define FAX_RECV_SHWITCHBD 19200
#define FAX_MODEM_HANDSHAKE     "AT&K3"
#define MODEM_INIT_STRING       "AT%T1S0=0E0Q0V1&C1&D3"
-----------------------------------------------------------------------
Date: Thu, 8 May 1997 08:25:39 +0000 ()
From: Felipe Rivera Marquez <felipe@informador.com.mx>
To: Gert Doering <gert@greenie.muc.de>
Subject: Motorola ModemSURFR entry for modems.db

Modem brand/model:      "Motorola ModemSURFR 28.8 External""
at+fmfr?                AT&T
at+fmdl?                HSM288xCF
at+frev?                CL2 V4.00
ati3                    Motorola ModemSURFR 28.8
ati4                    007040C0040000
at&v			STORED PROFILE 0:
			B1 E0 L1 M1 Q0 V1 W0 X4 &B1 &C1 &D2 &G0 &L0 &P0 &Q0 &R0 &S0 
			&X0 %A013 %C1 %G1 \A3 \C0 \G0 \J0 \K5 \N3 \Q3 \T000 \V0 
			\X0 -J1 "H3 "O032
			S00:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:045 
			S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S25:005 
			S26:001 S37:000 S72:000

tested on:              Linux 2.0.18 (Distribution RedHat 4.0)
working:                mgetty 
remarks:                &D2 sould be &D3 in the STORED PROFILE 0 (active
			DTR hang and reset modem) but it was easier to set
			&D3 in the init-string on mgetty.config
			Set toggle-dtr-waittime in mgetty.config to 2000, 
			it seems that 50 (the default) is not enough for 
			this modem.
			All the modems are working with a Comtrol
			Rocketport ISA 32 ports. Maybe you should decrease
			DO_CHAT_SEND_DELAY and toggle-dtr-waittime. I just
			set them high because i was getting mad and when
			the modems stopped going away, i just said to me:
			No more changes, don't touch the settings anymore
			:).
			I use the modems for data only.
			Some of the commands in the init-strings are
			unnecesary, but, well.... the modems are working
			without trouble.

contributor:            felipe@informador.com.mx

#define MODEM_CHECK_TIME -1
#define DEFAULT_MODEMTYPE "data"
#define DO_CHAT_SEND_DELAY 1000


-------------- mgetty.config

# global settings
init-chat "" ATZ OK AT OK AT&D3ELS2=255S0=0 OK
force-init-chat "" \\d\\d\\d\\d\\d\\d+++\\d\\d\\dATH OK ATZ OK AT OK
		AT&FELS2=255 OK ATS0=0&D3
toggle-dtr-waittime 2000

-----------------------------------------------------------------------
Date: Sun, 1 Jun 1997 20:31:35 +0200 (MET DST)
From: Peter Gerland <peter@peges.central.de>
To: Gert Doering <gert@greenie.muc.de>
Subject: Re: CYBERMOD und mgetty

Modem brand/model:      "Dr. Neuhaus CYBERMOD 28.8 V.34"
at+fmfr?                Dr. Neuhaus
at+fmdl?                LC 28.8 TI  DNT 1175
at+frev?                V.0.00.0680
ati0			28800
ati1			255
ati8			AT&T V.34 Datapump Version 2.5
ati+FDCC?		28800
			1,5,0,2,0,0,00                 
tested on:              Linux 2.0.30
working:                mgetty, sendfax
			mgetty-version 1.1.6
remarks:                Works after comment mg_m_init.c the line with
			"/* if ( mdm_command( "AT+FCLASS=0",fd) == FAIL) */"
			thanks to Gert Doering
contributor:            peter@peges.central.de
date:			21 May 97 22:30
#define FAX_COMMAND_DELAY 50
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT
#define FAXSEND_FLOW    FLOW_HARD | FLOW_SOFT
#define DEFAULT_PORTSPEED 38400
#define FAX_MODEM_HANDSHAKE    
#define MODEM_INIT_STRING       "AT&FS0=0M0L3\\\\q3\\\\J1"
-----------------------------------------------------------------------

Modem brand/model:      "Dr. Neuhaus FURY 14.4 TI"
at+fmfr?                Dr. Neuhaus Mikroelektronik GmbH
at+fmdl?                FURY (R) 14.4 Ti
at+frev?                Version 3.000
ati0			962
ati1			000
ati8			...
ati9			FURY (R) 14.4 Ti Version 3.000
			Data Pump Version  2.200
			MNP/V.42  Version  7.000
ati+FDCC?		962
			0,3,0,0,0,0,0,5
tested on:              Linux 2.0.30
working:                mgetty, sendfax
			mgetty-version 1.1.9
contributor:            bartels@bartels.com
date:			20 Oct 97

#define FAX_COMMAND_DELAY 50				(default)
#define FAXREC_FLOW     FLOW_HARD | FLOW_SOFT		(default)
#define FAXSEND_FLOW    FLOW_HARD | FLOW_SOFT		(default)
#define DEFAULT_PORTSPEED 38400				(default)
#define FAX_MODEM_HANDSHAKE    				(default)

-------------- mgetty.config

# port settings
modem-type cls2
switchbd 19200

-------------- sendfax.config

# port settings
modem-type cls2
ignore-carrier y
switchbd 19200

-----------------------------------------------------------------------
Contributor:    Nick Holloway <Nick.Holloway@alfie.demon.co.uk>
Modem:          ACCURA 33600, Model 5349GB, Version 6.20
at+fmfr?        Copyright 1995, 1996 Hayes Microcomputer Products, Inc.
at+fmdl?        ACCURA 33600
at+frev?        Version 6.20
tested on:      Linux 1.2.30, mgetty 1.0.0
working:        mgetty, sendfax
remarks:        The setting of S101 is just for distinctive ring.

mgetty.config:  speed 115200
                switchbd 0
                init-chat "" \d\d\d+++\d\d\dATZ OK ATS101=61 OK
                answer-chat "" AT+FCLASS=2;A CONNECT \c \r
-----------------------------------------------------------------------
Subject: Re: patch for mgetty
Date: Fri, 01 May 1998 10:11:17 +0200
From: Quercia Michel <quercia@cal.enst.fr>

Modem brand/model: 	"Kortex Adaptix 56000"
at+fmfr?		Venus K56FLEX kfav141 Serial s091097V
at+fmdl?		Venus K56FLEX kfav141 Serial s091097V
at+frev?		s091097V
ati0			KORTEX ADAPTIX 56K FRANCE V1.00 110 780 00 
ati1			0000
ati2			
ati3			Venus K56FLEX kfav141 Serial s091097V
ati4			KORTEX ADAPTIX 56K FRANCE V1.00 110 780 00
ati5			s091097V,0,05
ati6			
at+fdcc=?		(0,1),(0-5),(0),(0-2),(0),(0),(0),(0-7) 
at+vcid=?		(0-2)  
tested on:		linux 2.0.29
working:		mgetty (fax not tested)
remarks: poor doc, you'll have to phone Kortex (several times) to get info
	 about AT sequences. To get caller-Id report, send "at+vcid=1"
contributor:		quercia@cal.enst.fr

-----------------------------------------------------------------------
Date: Wed, 20 May 1998 21:18:27 +0200
From: Karel Vanthuyne <Karel.Vanthuyne@village.uunet.be>
Subject: Re: latest release of mgetty (1.1.14) solved the problems with my E-tech modem!

Modem brand/model:      E-Tech Golden Bullet E336RVP
ATJ                     E336RVP, 00, Ver 8.00, A75F, RCV336ACF/SP 
ATI0                    33600
ATI3                    V2.050-V34_ACF_DS1
ATI6                    RCV336DPFSP Rev 44BC
AT+FCLASS=?             0,1,1.0,80
tested on:              Linux 2.0.30 (RedHat 4.2)/UART 16550A
working:                vgetty
contributor:            Karel.Vanthuyne@village.uunet.be

changes in voice.conf:

port_speed 115200

policy.h:

#define DEFAULT_PORTSPEED       115200
#define MODEM_INIT_STRING       "ATV1E1&D3&C1X4&K3Q0W2N1L0S11=100"
#define MODEM_CMD_SUFFIX "\r"
#define DEFAULT_MODEMTYPE "auto"
#define DO_CHAT_SEND_DELAY 50
#define DATA_FLOW       FLOW_HARD

Remark: 

Note that this modem only supports fax class 1 and 1.0
Setting the modem-type to "auto" is harmless: vgetty doesn't detect fax
class 2/2.0 capability and just disables faxing.
Which is fine if you're only interested in using this modem for incoming
voice calls and data calls.
The modem doesn't seem to automatically distinguish between voice and
data, so I wrote a script to take care of that (caller has to press "0"
to get a data answering tone next time he calls).

However, it seems that work is in progress for fax class 1 support 8-)
I use efax for sending faxes right now.

-----------------------------------------------------------------------
Date: Wed, 22 Jul 1998 19:16:04 -0300
From: Claudemir Todo Bom <allgood@conection.com.br>
To: Gert Doering <gert@greenie.muc.de>, mgetty@muc.de
Subject: Re: Problems on sending to a Toshiba fax machine

Modem brand/modem:	"Yanco NetSpeed ESV33.6"
at+fmfr?		CIS
at+fmdl?		RM-3314E,VERSION 1.10.1a,04-05-02
at+frev?		VERSION 1.10.1a,04-05-02
ati3			same as at+fmdl?
tested on:		Linux 2.0.33
working:		sendfax, faxspool, faxrunq (mgetty not tested)
remarks:		Great work with fax transmission, not tested
			for incoming faxes and mgetty. Transmits faxes
			from Brazil to various european countries.
			Probably available only on Brazilian stores.

#define DEFAULT_MODEMTYPE "cls2"	/* or auto */
#define FAX_MODEM_HANDSHAKE "AT&K3" 	/* Rockwell based */
#define FAX_SEND_IGNORE_CARRIER		/* only tested with this */
#define FAXSEND_NO_XON			/* needed */


-----------------------------------------------------------------------
Date: Tue, 25 Aug 1998 21:22:57 +0300 (EEST)
From: Olli Arnberg <oar@leka.hut.fi>
To: gert@greenie.muc.de 
Subject: Thanks for 'modem-quirks' in mgetty-1.1.14 & XLink settings

Modem brand/model:	XLink V.34 + V.FC (black enclosure)
at+fmfr?
CIS

OK
at+fmdl?
MC-2814E
VERSION 0.20.6
05-04-03

OK
VERSION 0.20.6
05-04-03

OK
ati0
288

OK
ati3
MC-2814E
VERSION 0.20.6
05-04-03

OK
ati4
OK
at+fdcc=?
(0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7)

OK
at&v
ACTIVE PROFILE:
B0 E1 L2 M1 N1 Q0 T V1 X4 Y0 &C1 &D2 &G0 &L0 &M0 &P0 &R0 &S0 &T4 &X0 &Y0
%A000 %B28800 %C1 %D0 %E2 %N0 \A3 \C0 \G0 \J0 \K5 \M0 \N3 \Q3 \T000 \V2 \X0
S00:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:045 S08:002 S09:006 S10:014
S11:095 S12:050 S13:000 S18:000 S25:005 S26:001 S29:000 S30:000 S91:012

tested on:		Debian/GNU/Linux 2.0.0 (hamm), kernel 2.0.27
mgetty version:		1.1.14 (Debian 1.1.14-2)
working:		mgetty, sendfax
remarks:		sendfax and mgetty (only fax tested) work
contributor:            oar@cc.hut.fi (Olli Arnberg)

/etc/mgetty/mgetty.config:
# ----- port specific section -----
# Our XLink Rockwell modem, needs "switchbd 19200" to receive faxes
# properly (otherwise it will fail with "timeout").
port ttyXX
  speed 38400
  switchbd 19200

/etc/mgetty/sendfax.config:
# ----- port specific section -----
# Our XLink:
port ttyXX
  modem-type cls2
  ignore-carrier
## NO_XON before sending next fax page although Class 2 modem:
  modem-quirks 8
-----------------------------------------------------------------------
Date: Sat, 3 Oct 1998 09:28:44 +0200
From: Ulf Steinberg <ulmo@rz.uni-karlsruhe.de>

Modem brand/model:     USRobotics Sportster Message Plus
AT+FMFR?               ???
AT+FMDL?               ???
AT+FREV?               ???
ATI0                   5601
ATI1                   5D48
ATI4 U.S. Robotics 56K Message Settings...

     B0  E1  F1  L1  M1  Q0  V1  X4  Y0
     BAUD=115200  PARITY=N  WORDLEN=8
     DIAL=PULSE   ON HOOK
     [...]

ATI7
Configuration Profile...

Product type           Germany External
Product ID:            02206800
Options                V32bis,V.34+,x2,V.90
Fax Options            Class 1/Class 2.0
Voice Options          Speaker Phone, TAD
Clock Freq             92.0Mhz
EPROM                  256k
RAM                    32k

FLASH date             2/24/98
FLASH rev              12.1.14

DSP date               2/24/98
DSP rev                12.1.14

tested on:              Linux (SuSE 5.2)
                        Kernel 2.0.33
working:                sendfax, mgetty, vgetty

remarks:		Fax polling isn't working (due to the modem.)
			for vgetty, the AT+MCS=0 command is very important
			to "revive" the modem after a voice session.

contributor:		ulmo@rz.uni-karlsruhe.de
thanksto:		Michael Witschke

Defines in policy.h
#define MODEM_INIT_STRING "AT+MCS=0S0=0Q0&D3&C1" //To turn of the local mode
#define FAX_USRobotics //respectively modem-quirks 0x20 (Error +FHS:25...)

-----------------------------------------------------------------------
From: "Razvan Sandu" <rsandu@go.ro>
Subject: mgetty works fine with DAVICOM modems
Date: Sun, 15 Nov 1998 02:08:20 +0200

[..]
mgetty and sendfax works fine on my Pentium MMX 233 system, equipped
with an internal DAVICOM PnP voice/fax/data modem (an ISA board). So, I
hereby send you my configuration parameters, in order to be included in
modems database, if useful.

Modem information

ATI V3.00
ATI2 TEST OK
ATI3 DAVICOM DATA/FAX MODEM, DATE 97/09/22
ATI4 DAVICOM V.34+/FAX/VOICE/SPEAKERPHONE MODEM/Ver 1.09
ATI5 OK
ATI6 OK
ATI7 OK
AT+FCLASS=? 0,2,8

[..]
/etc/mgetty+sendfax/mgetty.config
debug 9
modem-type cls2
switchbd 19200
speed 115200
init-chat "" ATZ OK ATS0=3D0Q0E1V1&d2&K4 OK


/etc/mgetty+sendfax/sendfax.config
verbose y
debug 9
speed 38400
switchbd 19200
fax-devices ttyS3
modem-type cls2
modem-init ATZ
modem handshake AT&K4
dial-prefix ATDP
-----------------------------------------------------------------------
Date: Wed, 10 Mar 1999 15:06:43 +0800
From: "Peter T. Caffin" <pc@it.net.au>
Message-Id: <199903100706.PAA27593@belgarion.it.net.au>
To: gert@greenie.muc.de (Gert Doering)

Modem brand/model:      Dynalink 1428VQE  
at+fmfr?                ROCKWELL
at+fmdl?                AC/V34
at+frev?                CRS-02 AST 950921
ati3                    CRS-02 AST 950921
ati6                    RC288DPi Rev 0
tested on:              Linux 2.2.2
working:                mgetty, sendfax
mgetty.config:          speed 38400
                        modem-type cls2
                        switchbd 19200
(INSTALLED FROM A .RPM OF MGETTY-SENDFAX 1.1.14)
remarks: Looking at the Dynalink 9624AP, you'd think that using this
         modem would be a doomed exercise. Actually, it was a pretty
         easy modem to install and use. It's an older 28.8k model, so
         you're more likely to encounter it second-hand.
contributor:            Peter Caffin <pc@it.net.au>
date:                   Wed Mar 10 14:40:35 WST 1999
-----------------------------------------------------------------------

Anon7 - 2021